For service engineers

MRI cryogenics under control.

Track helium level, pressure and cooling across your MRI fleet. CryoPro alerts you within a minute when a reading crosses its limit.

Compatible with MM3 and MM4

Sample telemetry Normal
MRI · 1.5 T
Helium level
80.0%
Pressure
0.99PSI
Compressor
On

Features

Your fleet in one place

From a fleet-wide overview down to a single magnet monitor reading.

What needs attention comes first

Systems with an alarm or warning rise to the top. Each card shows the helium level, pressure, compressor state and time of the last reading.

no data

When a monitor stops sending readings, the value turns grey. The card keeps the time of the last update.

FleetDemo data

3 systems · 2 need attention

SystemHelium level
  • Novosibirsk · MRI 1.5 THelium below 60%
    59.6 %
  • St Petersburg · MRI 3 TWater temperature above 22 °C
    75.2 %
  • Kazan · MRI 1.5 TWithin limits
    80.0 %

From warning to recovery

One card follows the fault from the first warning to recovery. See who received the alert, who acknowledged it and what they did.

Sample incident history
  1. Warning · Water Temp 23.4 °CAbove the 22 °C limit. Incident opened.
  2. Telegram and pushDelivered to the system's subscribers.
  3. Alarm 26.8 °CAbove 26 °C. Escalated in the same card, with its own message.
  4. Service centre on-callAlarm unacknowledged for 15 minutes: e-mail, Telegram and push to the on-call engineer.
  5. Acknowledged · Irina Sokolova“Site chiller restarted, on my way.”
  6. Recovered 18.9 °CIncident closed; the whole history stays on the card.
Water temperatureDemo data

Incident · Water Temp

  1. Warning23.4 °C
  2. Alarm26.8 °C
  3. Recovered18.9 °C

Every deviation on the chart

Use the reading history to pinpoint a deviation and see how the system recovered.

  • Minimum and maximum, not just the average

    A short spike doesn't vanish into an hourly mean.

  • The limit of that day

    The chart shows the limit that was in force at the moment, even if the rule changed later.

  • A gap where there was no data

    The line never bridges missing readings. A lone reading shows as a dot.

  • Rules with a log

    Every limit change is recorded: who, when, old value, new value and why.

Helium levelDemo data

Kazan · MRI 1.5 T · 30 days

80.0 %
80%75%70% 25 Oct9 Nov24 Nov
Minimum 68.0 %Maximum 81.4 %

Parameters

The ten values an engineer needs

Named the same as in the app and the web dashboard. The monitor's counters and service channels are shown only to developers and stay out of the way.

Helium

He Level
Liquid helium level in the magnet
%
He Pressure
Helium vessel pressure
PSI

Cryogenics

Coldhead RuO
Cold-head temperature
K
Recon RuO
Recondenser temperature
K
Recon Si410
Recondenser temperature
K
Shield Si410
Thermal shield temperature
K
HDC
Heater duty cycle: the share of time the magnet heater is on
%

Cooling

Water Flow
Cooling water flow
L/min
Water Temp
Cooling water temperature
°C
Compressor
Helium compressor
On / Off

Notifications

Alarms reach you where you'll see them

Everyone chooses which systems to hear about, from which level, and whether to be told about recovery.

Web dashboard

The whole fleet, charts, monitoring rules, incident log.

iPhone

Push, the incident card, one-tap acknowledgement.

Apple Watch

The alarm on your watch face, acknowledge from the wrist.

Telegram

A message with Open, Acknowledge and Mute buttons.

E-mail

Backup channel for Alarms and for the on-call engineer.

System status on your wrist
Apple Watch: two systems need attention.
Apple Watch: a system's screen, helium level 79.99 %, within limits.
How alerts are grouped and muted

If several systems at one site lose connection at once, you get one message, not ten. Muting a system takes a reason, and the incident is still recorded.

Connecting

Nothing to install at the site

The magnet monitor sends its data to the CryoPro server itself. Works with MM3 (Magnet Monitor III) and MM4 monitors.

  1. The system is added to CryoPro

    Your service organisation adds it by the monitor's serial number and assigns it to a site.

  2. The monitor gets a new address

    The CryoPro server address is entered in the monitor's settings. Nothing else is needed at the site.

  3. Data starts flowing

    The monitor registers with the server, and its readings appear in the dashboard and the app.

Who sees what

Access is granted by the service organisation. A site sees its own systems, a service centre sees the systems it services.

Sign-in

Administrators and engineers who can change rules sign in with a one-time code from an authenticator app.

The server is watched too

If CryoPro itself has a fault, systems don't get a false “offline”: the platform team is alerted instead.

Contact CryoPro